제품소개

  • Frankonia
  • HiLo
  • PTL
  • 기타
  • 문의 및 상담
  • 문의게시판

HiLo

Home > 제품소개 > HiLo

제목 Hilo 사의 종합 카탈로그입니다. 등록일 2018.07.25 18:26
글쓴이 YM tech 조회 1580
안녕하세요.
Hilo 사의 종합 카탈로그입니다.
https://blog.naver.com/twoyoung_office/221326402533 여기에서 선명한 이미지 파일을 얻으실 수 있습니다.
문의사항 있으신 분은 연락 주시기 바랍니다.
감사합니다.


EMC 종합 카탈로그-Hilo page1.jpg

EMC 종합 카탈로그-Hilo page2.jpg



Hilo - Automotive EMC Test System
Car-test-system14 CAR-SYS 14
- according to ISO 7637, ISO 16750, ISO 21848
- #1 1-5/2000㎲ , 600V, ISO
- #1 1-5/1000㎲, 600V, ISO/SAE
- #2a 1/50㎲, 600V, ISO
- #3a 5/100㎱, 800V, ISO
Transient Emission CAR-TE 14
- according to ISO 7637, CISPR 25, CISPR 16-1-2
- Triggerable load switch
- Battery current: 50/100/200A (800V)
- Shunt resistors integrated, switchable 10Ω/20Ω/40Ω
Load Dump Generator CAR PG 2804
- According to ISO 16750-2
- Pulse #5, 10/400ms, 200V, Ri=0.5Ω
- Test A, 10/350ms, 200V, Ri=1Ω
- Test B, 10/200ms, 200V, 2Ω
            10/100ms, 180V, 4Ω
            10/50ms, 150V, 8Ω
Automotive Power Fail Simulator CAR-PFS-80 I/II/III
- according to ISO 7637, ISO 21848, etc,.
- Voltage dips and interruptions
- Rise/fall time < 1㎲
- Battery voltage: 80V DC
- Battery current: I 50A / II 100A / III 200A
Amplifier Load Dump CAR LD 3x PS 66-55
- according to ISO 7637-2, ISO 16750-2
- Manufacturer: LV 124, LV 148, VW 8000/8100, VG96916
- Ri=0.5, 1, 2, 4, 8, 10Ω
Superimposed Sinus AC Generator CAR SS A1250
- according to ISO 16750-2
- Manufacturer: LV 124, LV 148, VW 8000, VW 8100
- Frequency: 0 ~ 30kHz, Current 30A
Power Supply to expand
the CAR-SYS  PS 74-220
- according to ISO 7637-2, 
   ISO 16750-2
- Voltage 66V ~ 74V, 
  Current 55A - 220A
ESD simulator  SESD 30000
- according to IEC 61000-4-2, 
   ISO 10605, TR 10605
- 30kV air and contact discharge
- Battery and main operation
- Automatic charge absorber integrated
ESD simulator  SESD 230
- Battery or mains operation
- 30kV air and contact discharge
- IEC 61000-4-2 (150 pF/330 Ohm)
- Predefined tests - standard and 
   others
Compact EMC tester Multi CE5
- according to IEC 61000-4-4, Burst 5kV
- according to IEC 61000-4-5, Surge 5kV, 2.5kA
- according to IEC 61000-4-8, Magnetic field 50/60 Hz
- according to IEC 61000-4-9, Magnetic field 8/20 ㎲
- according to IEC 61000-4-11/29, voltage dips/variation

Varistor tester PG 6-250 (combination wave generator)
- Surge voltage: 1.2/50 ㎲, 6 kV
- Surge current: 8/20 ㎲, 2.4 kA
- According to CCITT, ITU-T: 10/700 ㎲

High-voltage impulse generator PG 6-364 
- Lightning surge: 1.2/50 ㎲
- Switching surge: 10/700 ㎲, 0.5/700 ㎲, 1.0/700 ㎲, 
                         0.5/1000 ㎲, 1.0/1000 ㎲
- Energy: 20 J/ 400 J
- According to CCITT, ITU-T, IEC, VDE

Impulse generator EMC 2015
- Impulse current
  25 kA, 8/20 ㎲
  5 kA, 10/50 ㎲
  600 A, 10/350 ㎲
  300 A, 10/700 ㎲
  200 A, 10/1000 ㎲
- Impulse voltage
  10 kV, 10/700 ㎲ 
- Combination wave
  2*10 kV, 1.2/50 ㎲
  2*10 kA, 8/20 ㎲
Combination Wave Generator PG 12-804
- according to IEC 61000-4-5 
  and IEEE 587
- Surge voltage 1.2/50 ㎲: 
   0.2 ~ 12 kV
- Surge current 8/20 ㎲: 
   0.1 ~ 6 kA

Hilo - ESD Generators
Hilo - Multifunctional Generators
Hilo - Surge(Hybrid) Generators
Frankonia - Conducted Immunity
Frankonia - Radiated Immunity
Frankonia - Anechoic Chambers
Surge Test PG 24-2500
- according to IEC 61000-4-5, IEEE 587
- Surge Voltage: 1.2/50㎲, up to 24 kV 
- Surge Current 8/20㎲, up to 12 kA
- max stored energy: 2500 J
- Safety test cover: PA 504 
Hilo - Ringwave Generators
Ring-wave IPG 612T
- according to IEC 61000-4-12
  And IEC 1008-1 (RCCB’s)
- Output voltage: 0.2~6 kV
- Frequency: 100 kHz
- Rise time: 0.5 ㎲
Magnetic field IPG 2553
- according to IEC 61000-4-10
- Oscillation frequencies: 
  100 kHz or 1 MHz 
- Field strength: 
   10 A/m to 100 A/m
Damped Oscillatory wave test IPG 2554
- According to IEC 61000-4-18
- Slow damped oscillatory: 100 kHz, 1 MHz
- Fast damped oscillatory: 3 MHz, 10 MHz, 30 MHz
- Coupling / decoupling network: 3-phase, 16A / 250V
Hilo - Telecom Generators
Front-chopped-wave generator IPG 506 SYM
- according to CCITT/ITU-T, K12
- 5kV impulse: 100V/㎲~5000V/㎲
- Insulation resistance: 
  0.5kΩ ~ 3 GΩ
- Measurement of DC spark-over
  voltage for 3-Pole Gas
  Discharge Tubes
High-Voltage Impulse Generator PG 12-1440
- according to CCITT-K17 / K20-
  K22, ITU-T/K44, IEC 61000-4-5, 
  VDE 0847
- Lightning Surge:
   1.2/50 ㎲, 0.5~12 kV
- Switching Surge: 
  10/700 ㎲, 0.5~12 kV

Surge Current Generator 
PG 6-432
- according to CCITT-K12
- Surge current: 5~100A x 2
   10/700 ㎲, 10/1000 ㎲
- Impulse Life Test, Hold-over Test
Hilo - Impulse Voltage Generators
HV-Impulse Generator 
IPG 1218
- according to IEC 60664, VDE
  IEC 60335, IEC 60060
- Surge testing: 1.2/50 ㎲
- Test voltage: 0.25 ~ 12 kV
- Insulation test
HV-Impulse Generator 
IPG 255
- according to IEC 60255, 
  IEC 61036, VDE 0435 part 303
- Impulse voltage: 1.2/50 ㎲
  0.5J, Rs=500Ω
- Voltage: 0.8/1/1.5/2.5/4/5/6 kV 
              and 8kV
- Insulation test
Impulse Voltage Tests of Solar Modules PG 20-100
- according to IEC 61730-2 Ed.2
- Waveform: 1.2/50 ㎲
- Test voltage: 0.8 ~ 20 kV
- Capacitances: 10nF ~ 183nF
Impulse Wave Generator
PG 12-400
- according to IEC 60060-1, 
  IEC 61010-1, IEC 60664-1
- Waveform: 1.2/50 ㎲
- Test voltage: 0.2 ~ 12 kV
- Serial resistor 40Ω
Hilo - Impulse Current Generators
HV-Surge Current Generator
PG 6-400
- according to IEC 60060, 
   IEC 62475-2
- Waveform: 8/20 ㎲
- Test voltage: 0.2 ~ 6 kV
- Test current: 10 kA
Surge Current Generator
PG 10-10000
- according to IEC 60060, 
   IEC 62475-2
- Waveform: 8/20 ㎲
- Test current: 2~50 kA x 2
- Charging voltage: 10 kV
- Pulse current test of Surge 
  protection devices
Surge Current Generator PG 20-14000
- according to IEC 61636-11, IEC 62475
- Waveform: 8/20 ㎲
- Test voltage: 0 ~ 20 kV
- Test current: 5 ~ 100 kA
- Energy: 14000J
- Charging time for max: <117 sec
- Pulse repetition rate for 100 kA: 1/117sec
- Pulse repetition rate for 40 kA: <1/60 sec
- Output pulse polarity: POS/NEG
Hilo - AC DC Test Equipment
Alternating Voltage Testing
AC-TESTER 6
- according to IEC 60335, 
  IEC 60204, IEC 60598, IEC 60745
- Test voltage: 10 ~ 10,000 V
- Test current: 1 ~ 100 mA
- Short circuit current: >200 mA
- Rise of sinus voltage ramp:
   0.1 kV/s ~ 10 kV/s
High-voltage measurement
HVM 2015
- Direct high-voltage input: 10 kV
Hilo - Coupling Network (CDN)




와이엠테크
서울특별시 성동구 아차산로17길 57 일신건영휴먼테코 703호
+82-2-956-3469 / +82-10-3373-3469
E-mail: sales@ym-tech.kr
EMC/Safety Standard Test System
Coupling/Decoupling Network CDN 12416 
- according to IEC 61000-4-4, IEC 61000-4-5
- Power: 3*400V, 50/60 Hz, 16A (10A DC)
- Max. test voltage Surge: 12 kV
- Max. test voltage Burst: 5 kV
- Option voltage: 3*690 V, 50/60 Hz

Coupling/Decoupling Network CDN 12432 
- according to IEC 61000-4-4, IEC 61000-4-5
- Power: 3*400V, 50/60 Hz, 32A (20A DC)
- Max. test voltage Surge: 12 kV
- Max. test voltage Burst: 5 kV
- Option voltage: 3*690 V, 50/60 Hz

Coupling/Decoupling Network CDN 124100 
- according to IEC 61000-4-4, IEC 61000-4-5
- Power: 3*400V, 50/60 Hz, 100A (100A DC)
- Max. test voltage Surge: 12 kV
- Max. test voltage Burst: 5 kV
- Option voltage: 3*690 V, 50/60 Hz

Coupling/Decoupling Network 
CDN 124250 
- according to IEC 61000-4-4, 
   IEC 61000-4-5
- Power: 3*400V, 250A (250A DC)
- Max. test voltage Surge: 12 kV
- Max. test voltage Burst: 5 kV
- Option voltage: 3*690 V, 50/60 Hz

www.hilo-test.de
High voltage test of components
HTS 20-10
- according to IEC 61643-11
- Isolation test: 20 kV
- Limit current: 10 mA
- Rate of rise: 10 kV/s
Broadband High-voltage Dividers
HVT 300 RCR
- Rated input voltage: 300 kV(DC)
                             230 kV(AC)